CURRENT INTEGRATIVE ENGINEERING

ISSN NO : 2995-6307

Current Integrative Engineering is dedicated to providing a platform for the exchange of cutting-edge research and innovative solutions across various engineering disciplines. Our mission is to foster collaboration and knowledge sharing among engineers, researchers, and industry professionals. We aim to bridge gaps in understanding, encourage interdisciplinary collaborations, and contribute to the collective advancement of engineering knowledge and its practical applications. Through our diverse scope, we strive to drive innovation, sustainability, and progress in the field of engineering.

  • 498
    Views
  • 0
    CrossRef citations to date

Analysis The Effect Of Magnet Structure On The Unbalance Magnetic Pull Of Fractional Slot Number Type In Permanent Magnet Machine

1 Dept. Of Electrical Engineering, Atma Jaya Catholic University, Jakarta, 12930,,Indonesia   |   2 Dept. Of Electrical Engineering, Trisakti University,Indonesia   |   3 Indonesia,Indonesia   |   4 Research Center For Energy Conversion And Conservation, National Research And Innovation Agency, 40135,,Indonesia   |   5 Dept. Electrical And Computer Engineering, Auburn University, 36849,,United States of America

Volume 2

Issue 1

Page: [7 - 14]

Published Online: February 5, 2024

  • Abstract

    Within This Study, The Effect Of Magnet Structure On The Unbalanced Magnetic Draw (UMP) Of Fractional Slot Number Permanent Magnet Machines (PMMs) Was Methodically Investigated. The Literature Revealed That Fractional Slot Number PMMs Use A Variety Of Magnet Structure Configurations, Including Radial, Parallel, And Hybrid Arrangements. Different Magnet Configurations Were Discovered To Affect The Distribution Of Magnetic Flux Density, Thereby Impacting UMP Concentrations. The Effect Of Various Magnet Geometries, Including Arc, Rectangular, And Trapezoidal, On UMP Was Examined. Moreover, The Selection Of Magnet Materials, Such As Ferrite, Neodymium-Iron-Boron, And Samarium-Cobalt, Influenced The Magnetic Field Distribution And UMP Characteristics.Due To Their Particular Slot And Pole Combinations, Fractional Slot Number PMMs Were Found To Be More Susceptible To UMP Than Other PMM Varieties. Unbalanced Forces Caused By UMP Resulted In Unwanted Vibrations, Increased Noise Levels, And Possible Machine Durability Issues. Numerous Factors Influence UMP In Fractional Slot Number PMMs, Including The Number Of Slots And Poles, The Length Of The Stator-Rotor Air Gap, The Magnet Pole Breadth, And The Magnet Thickness. The Level Of UMP Was Affected By The Interaction Of These Factors With Magnet Structure Configurations.

    Keywords: Magnet Structure Magnetic Pull Fractional Slot Number Permanent Magnet Machine

  • Figures

    Figure Image

  • References

      • [1]Al-Asadi, M. J., Salman, T. I., Al-Bayati, A. R., & Ghosh, S. (2021). Effect of curing procedures on mechanical properties of fiberglass ferrocement. Composite Structures, 256, 113166.
      • [3]Alotaibi, A. I., Almusallam, T. H., & Shameem, M. (2019). Life cycle assessment of fiberglass ferrocement compared to traditional roofing materials. Journal of Cleaner Production, 216, 53-64.
      • [4]Aziz, S. N. A., Alengaram, U. J., Jumaat, M. Z., & Mannan, M. A. (2020). Seismic behavior of fiberglass ferrocement reinforced concrete structures. Construction and Building Materials, 251, 118923.
      • [5]Balaguru, P. N., Ramakrishnan, V., & Sankar, S. S. (2016). Flexural and tensile properties of fiberglass ferrocement panels. Construction and Building Materials, 121, 332-341
      • [6]Elchalakani, M., Mohammed, A., & Hadi, M. (2018). Challenges in the use of fiberglass ferrocement for largescale roofing. Engineering Structures, 176, 194-204
      • [7]Ghosh, S., Sharma, A., Bandyopadhyay, S., & Dutta, S. (2017). Case study of a commercial building with fiberglass ferrocement roofing in a coastal region. Case Studies in Construction Materials, 7, 167- 175.
      • [8]Rahman, M. M., Laskar, A. I., & Hussain, M. M. (2018). Environmental durability of fiberglass ferrocement. Journal of Composites for Construction, 22(6), 04018056.
      • [9]Sanjayan, J. G., Subramani, T., & Paramasivam, P. (2019). Smart composite materials for real-time structural monitoring in roofs. Composite Science and Technology, 185, 107740
  • Article Metrics

    Views

    498
  • Copyright and Permissions

    At Guinness Press, authors retain the copyright for all articles published in our journals. These articles are licensed under the open-access Creative Commons CC BY 4.0 license, granting free access for reading and download. Additionally, the original published version must be appropriately cited when reusing or quoting the article. These terms ensure widespread accessibility while ensuring proper attribution to the authors.

    All content published by Guinness Press is safeguarded by international copyright and intellectual property regulations. We kindly request that you honor these protections when utilizing our materials.

    For further information, please contact us at info@guinnesspress.org.